2-4
Cisco IE 3010 Switch Hardware Installation Guide
78-19581-02
Chapter 2 Switch Installation
Installing the Switch
Installing the Switch
Rack-Mounting, page 2-4
Wall-Mounting, page 2-15
Note If the switch is wall-mounted in an enclosure, follow these minimum clearances:
- Sides of switch (facing up and facing down): 3.75 in. (9.52 cm)
- Port side 3.0 in. (7.62 cm)
- Power supply side: 5.25 in. (13.33 cm)
- Cover side (side not facing wall): 1.75 in. (4.44 cm)
- Base side (facing wall): 0 in. (0 cm)
Rack-Mounting
To rack-mount the switch, select the rack size and follow the steps in these sections:
Attaching Brackets for 19-Inch Racks, page 2-5
Attaching Brackets for 19-Inch Racks for IP-30 Compliance (Optional), page 2-6
Attaching Brackets for 23-Inch Racks, page 2-12
Attaching Brackets for ETSI Racks, page 2-13
Rack-Mounting the Switch, page 2-14
.
Warning
For mounting railway-application equipment and for EN50155 standard compliance, the switch must
be installed only in a rack mid-mounting position. If you install the switch in a front rack-mounting
(cable side or power supply side) position or in a wall-mounting position, a mechanical failure can
occur that results in the switch becoming detached from the rack.
Statement 403
Warning
To prevent bodily injury when mounting or servicing this unit in a rack, you must take special
precautions to ensure that the system remains stable. The following guidelines are provided to
ensure your safety:
This unit should be mounted at the bottom of the rack if it is the only unit in the rack.
When mounting this unit in a partially filled rack, load the rack from the bottom to the top with the heaviest
component at the bottom of the rack.
If the rack is provided with stabilizing devices, install the stabilizers before mounting or servicing the unit in
the rack.
Statement 1006