2-18
Cisco IE 2000 Switch Hardware Installation Guide
OL-25818-04
Chapter 2 Switch Installation
Connecting to Power
Note This section does not apply to PWR-IE50W-AC-IEC, which has pluggable IEC connector.
Connecting the AC Power Source to the Power Converter
Caution AC power sources must be dedicated AC branch circuits. Each branch circuit must be protected by a
dedicated two-pole circuit breaker.
Caution Do not turn on AC power until the wiring is secured.
Step 1 Remove the plastic cover from the input power terminals and set it aside.
Step 2 Insert the exposed ground wire lead into the power converter ground wire connection. Ensure that only
wire with insulation extends from the connector. See Figure 2-9, item 1. Note that the position of the
power converter may vary on different switch models.
Figure 2-9 Connecting AC Power
Step 3 Tighten the ground wire terminal block screw.
Note Torque to 8 in.-lb, not to exceed 10 in-lb.
1 Ground 3 AC line
2 AC neutral