11.0
Seed Calibration (continued)
Open Hopper Flow Door
4. Have a collection bin ready
to catch seed from the HCBT Hopper Housing. Open the
HCBT hopper ow door (Pull UP on the lip and then let it
DOWN). Use the OPEN/CLOSE seed gate on the seed source
bin above the HCBT inlet hopper to start the seed ow.
5. Time the seed ow for one minute.
Close the OPEN/CLOSE seed gate on the seed source bin.
Then close the HCBT hopper ow door.
Seed Flow
SEED
6. Weigh the seed that has gone through in one minute.
Write down your time and calculate the output per minute.
Use the following example with your choice of weight per
minute in place of the 600 pounds.
Example: 600 pounds discharge in one minute.
If 600 pounds is an acceptable capacity, leave the hopper
ow door in the position you have set.
If the capacity is too
high then reduce the opening on the
hopper ow door and calibrate again.
If the capacity is too low then increase the opening of the
hopper ow door and calibrate again.
Repeat steps
4-6 until you achieve your required feed
capacity.
Hopper Flow Door handle
Hopper Flow Door handle
DOWN TO REDUCE
UP TO INCREASE