SYSTEM
Frequency Response (-3dB)
(1)
90Hz - 25kHz 75Hz - 22kHz
Frequency Range (-10dB)
(1)
80Hz - 30kHz 55Hz - 24kHz
System Sensitivity (1W @1m)
(2)
88dB 90dB
1W = 2.45V for 6 Ohms
Dispersion 90 90
Degrees conical -6dB
Low Frequency Driver 1x 110mm (4.50”) 1x 165mm (6.50”)
Mineral loaded polypropylene
High Frequency Driver ICT
TM
ICT
TM
Crossover 7kHz 7kHz
Inductively Coupled ICT™
Directivity Factor (Q) 1kHz to 10kHz 5.3 averaged 10.5 averaged
Directivity Index (DI) 1kHz to 10kHz 6.6 averaged 8.4 averaged
Rated Maximum SPL
(2)
Average 105dB 107dB
Peak 111dB 113dB
Power Handling Average 50W 60W
Programme 100W 120W
Peak 200W 240W
Recommended Amplifier Power 100W @ 6 Ohms 120W @ 6 Ohms
Nominal Impedance 6 Ohms 6 Ohms
Distortion 10% Full Power (5.5V) 2nd Harmonic 3rd Harmonic (6.0V) 2nd Harmonic 3rd Harmonic
250Hz 2.00% 0.26% 1.86% 0.12%
1kHz 0.53% 0.19% 1.17% 0.54%
10kHz 2.50% 0.35% 1.10% 0.04%
Distortion 1% Full Power (1.73V) 2nd Harmonic 3rd Harmonic (1.9V) 2nd Harmonic 3rd Harmonic
250Hz 0.65% 0.09% 0.70% 0.14%
1kHz 0.144% 0.11% 0.45% 0.39%
10kHz 0.52% 0.298% 0.25% 0.065%
CONSTRUCTION
Enclosure Weather resistant high impact polystyrene (HIPS), IP64 to EN60529 (IEC529)
Grille Steel, with weather resistant coating
Finish Textured black or white paint with matching rubber trims
Factory fitted custom trim colours available to special order
Connectors Removable locking Euroblock type connector
with screw terminals and "loop through" facility
Fittings 1 x socket for K-Ball™ bracket and 2 x M8 yoke bracket inserts
Supplied Accessory Yoke bracket
Dimensions 240.7 x 155.0 x 162.0mm 357.5 x 230.0 x 223.2mm
9.47 x 6.10 x 6.38” 14.08 x 9.05 x 8.79”
Weight 2.2kg (4.85lbs) 3.7kg (8.15lbs)
TRANSFORMER VERSIONS Di5t Di6t
Specifications as above except:
Transformer Taps 70V
30W / 15W / 7.5W / 3.75W / OFF 60W / 30W / 15W / 7.5W / OFF
Rotary switch & Low Impedance operation & Low Impedance operation
mounted under trim
100V
30W / 15W / 7.5W / OFF & 60W / 30W /15W / OFF &
Low Impedance operation Low Impedance operation
Rated Maximum SPL
(2)
Average 103dB (using 30W transformer tap) 107dB (using 60W transformer tap)
Weight 2.7kg (5.94lbs) 5.0kg (11.02lbs)
See Passive models above for max SPL figures on low impedance settings.
ICT
TM
MODELS
Notes:
(1) Average over stated bandwidth. Measured at 1 metre on axis in an anechoic chamber
(2) Unweighted pink noise input, measured at 1 metre in an anechoic chamber
A full range of measurements, performance data, and Ease
TM
Data can be downloaded from www.tannoy.com
Tannoy operates a policy of continuous research and development. The introduction of new materials or manufacturing methods will always equal or exceed the published specifications,
which Tannoy reserves the right to alter without prior notice.
*
*
Di Manual 8-2-07 AW:Layout 1 21/2/07 10:52 Page 12