HeadsetUSA PAS 400 Portable Speaker User Manual


 
freePORT PAS 400 Version 060328 7
If a small amount of moisture or dew has formed on the cabinet or the back panel, e.g. after
transportation or storage, carefully wipe off all of the moisture with a clean, soft cloth and
allow the unit to acclimate in a warm, dry environment for at least two hours before applying
power to the unit or operating it.
1.4 Set Up
1.4.1 Tripod or Pole Mounting
The freePORT PAS 400 enclosure is fitted, on the bottom, with a standard 35 mm mounting
flange for tripod or pole mounting. It can also be mounted to the LST 60 spiked pole for
outdoor use on uneven ground.
With the LH 33 tilt connector the tilt angle can be adjusted from 0° (perpendicular) to 15°.
For maximum tilt-angle adjustability, the LH 26 fork mounting bracket can be attached to
the PAS 400 with 2 x M8 knurled thumbscrews and then combined with an LH 28 tripod
stand adapter to mount it to a tripod. The speaker can then be rotated and tilted to the
optimum angle for the listeners.
1.4.2 Wall or Ceiling Mounting
For hang-mounting, the top of the enclosure has two M8 threaded attachment points (115
mm spacing) for attaching an LH 29 TV spigot for mounting to cross beams or light stands.
For wall mounting with maximum adjustability, the speaker can be attached, via the 35 mm
mounting flange on the bottom, to an LH 120 wall mount bracket. The speaker can then be
rotated and tilted (10 - 25°) to the optimum angle for the listeners.
1.4.3 Positioning & Alignment
Position the loudspeakers so that they:
y will not be directly aimed at any open microphones
y will be as far away from the microphones as possible - especially important with sensitive
or long-distance microphones
y will be at the front of the stage or more forward than the microphones (in relation to the
listeners)
1.5 Power / Mains Connection (1)
The freePORT PAS 400 is available in the following AC mains voltage configurations:
y 230 Volt AC / 50 Hz
(supplied with a German Schuko mains cable connector)
y 120 Volt AC / 60 HZ
(supplied with a USA 3-prong mains cable connector)
y 100 Volt AC / 50-60 Hz
(supplied with a USA 3-prong mains cable connector)
Before connecting to the mains power supply:
̈ Verify that each PAS 400 system matches the mains voltage at the site!
̈ Do not disconnect any part of the ground connection! When powered from an AC mains
supply, the system must only be operated with a proper ground connection!
The (supplied) mains cable connector may not match the AC outlet type in some countries.
Only a qualified electrician should change the AC connector and the proper ground-
connection must be made.
Attention!