EMC CLARiiON CX300, CX500, and CX700 Initialization Guide
Initializing the Storage System
12. Specify the following for SP B:
a. IP address
b. Hostname
c. Subnet mask
d. Gateway address for SP B
e. Peer IP address for SP A
f. If desired, for example, for added security (see the caution
below), change the management port setting to 2162/2163.
CAUTION
!
Be sure that this is the management port whose setting you want to
change. If you later want to change it back, you must remove the
node from its domain before you can change its port setting from
the default.
If you do change the management port setting, you will need to
append the URL with :2162 whenever you want to manage the
storage system.
For a description of Navisphere 6.X security features, refer to the
EMC Navisphere Version 6.X Security Administrator’s Guide.
13. Verify that SP A has rebooted completely; the amber Fault LED on
SP A should not be on or blinking.
14. Click Apply Settings.
After about 30 seconds, a confirmation screen opens, similar to
the one in Figure 5. The display lists the network configuration
information you entered in step 12, and includes a message
informing you that SP B is rebooting.