Outdoor Antenna Grounding: If an outside antenna is con-
nected to the receiver, be sure the antenna system is ground-
ed, so as to provide some protection against voltage surges
and built up static charges. Section 810 of the National
Electrical Code, ANSI/NFPS No. 70-1983, provides information
with respect to proper grounding of the mast and supporting
structure, grounding of the lead-in wire to an antenna discharge
unit, size of grounding conductors, location of antenna-dis-
charge unit, connection to grounding electrodes, and require-
ments for the grounding electrode. See illustration below.
19
SAFETY INSTRUCTIONS
Read Instructions: All the safety and operating instructions
should be read before the appliance is operated.
Retain Instructions: The safety and operating instructions
should be retained for future reference.
Heed Warnings: All warnings on the appliance and in the oper-
ating instructions should be adhered to.
Follow Instructions: All operating and use instructions should
be followed.
Water and Moisture: The appliance should not be used near
water. For example, near a bathtub, washbowl, kitchen sink,
laundry tub, in a wet basement, or near a swimming pool, etc.
Wall or Cabinet Mounting: The appliance should be mounted
to a wall or cabinet only recommended by the manufacturer.
Heat: The appliance should be situated away from heat
sources such as radiators, heat registers, stoves, or other appli-
ances (including amplifiers) that produce heat.
Power Supply: The appliance should be connected to a power
supply only of the type described in the operating instructions
or as marked on the appliance.
Cleaning: The appliance should be cleaned only as recom-
mended by the manufacturer.
Power Lines: An outdoor antenna should be located away
from power lines.
Object and Liquid Entry: Care should be taken so that objects
do not fall, and liquids are not spilled into the enclosure through
openings.
Antenna Lead-In Wire (B)
Antenna Discharge
Unit (C)
To Receiver
Mast
Ground
Clamp
Ground
Wire
(A,B)
Grounding
Clamps
Grounding Electrode
Driven 8’ Into the Earth
2.44 Meters
Example of Antenna Grounding as per
National Electrical Code. Instructions
Contained in Article 810-"Radio and
Television Equipment"
A. Use No. 10 AWG (5.3mm2) copper, No. 8 AWG (8.4mm2) aluminum, No. 17
AWG (1.0mm2) copper clad steel or bronze wire, or larger as ground wire.
B. Secure antenna lead-in and ground wires to house with stand-off insulators
spaced from 4 feet (1.22m) to 6 feet (1.83m) apart.
C. Mount antenna discharge unit as close as possible to where lead-in enters
house.