Bosch Appliances PB10-CD Portable Radio User Manual


 
12
Use of 12V Outlet
Note: Do not insert any device that pulls more than 1 Amp
or else the fuse will open.
12V outlet will not operate
from battery pack.
1.
Lift the rubber lid marked with 12V of the jack and insert
the plug of the device or the appliance.
2. Close the lid as soon as you finish using the outlet to
prevent any other things from entering the jack.
3. If no power is available then check fuse.
Changing fuse
1.
Unscrew fuse cap in counterclockwise direction.
2. Replace fuse. Replace only with
a metric 5x20mm fast
acting 1 Amp fuse
.
3. Tighten fuse cap assembly in clockwise direction.
Do not bypass the fuse or use any other
fuse except what is specified, as it may
cause damage to the unit.
Changing Clock Batteries
1.
Open battery bay door.
2. Remove AAA battery cover.
3.
Remove old batteries and dispose of properly.
4.
Insert new AAA batteries. Do not use mismatched
batteries, use only new Alkaline batteries.
Problem Checkpoint Remedy
Audio Unit doesn’t 1. Is power cord properly connected ? 1. Plug in AC power cord.
function.
2. Is the Bosch battery pack installed or
2. Make sure battery is completely inserted.
inserted properly?
3. Does the battery need charging? 3. Plug in power cord and insert battery.
It is noisy or weak 1. Is there any facility interfering with
1. Move unit to new location away from
in radio receiving. the unit.
interference.
2. Is there any interference to the 2. Turn the unit in different directions.
internal FM antenna?
12V DC outlet 1. Is 1 amp fuse properly inserted? 1. Insert 1 amp fuse.
doesn’t function 2. Has the 1 amp fuse blown open? 2. Replace fuse.
4-Way Power outlet 1. Is power cord properly connected? 1. Plug in AC power cord.
does not function
2.
Is red light illuminated on outlets?
2. Press reset button.
3. Perform GFCI testing procedure.
Does unit suddenly 1. Is power cord properly connected 1. Plug in power to unit.
fail to work to unit?
2. Is the LCD displaying that there is 2. Software in unit needs to be reset. Remove battery
power to the unit?
from unit and unplug AC power cord, wait for 30
seconds and reconnect AC power cord.