81
Configuration
Control Panel Parameters
6/15/09 S4M User Guide 13290L-004 Rev. A
DELIM. CHAR
(ZPL mode only)
Set Delimiter Character
The delimiter character is a two-digit hexadecimal value used as a
parameter place marker in ZPL/ZPL II format instructions. See the ZPL II
Programming Guide for more information.
Note • Do not use the same hexadecimal value for the control,
command, and delimiter character. The printer must see different
characters to work properly.
Range: 00 to FF
Default Value: 2C (comma)
To modify this parameter:
• To increase the value, press the up arrow.
• To decrease the value, press the down arrow.
HEXDUMP
Hex Dump
The hexadecimal dump mode is a troubleshooting tool for checking the
interconnection between the printer and the host computer. For more
information, see Communications Diagnostics Test on page 121.
Selections: NO, YES
Default Value: NO
To modify this parameter:
• Press the up or down arrow to scroll through the selections.
REPRINT MODE
(ZPL mode only)
Reprint Mode
When Reprint Mode is enabled, the
~PR ZPL command can be used to
reprint the last label. If the Reprint feature is disabled, the
~PR command
is ignored. (Equivalent to the reprint mode parameter in the
^JJ ZPL
command.)
Selections: ENABLED, DISABLED
Default Value: DISABLED
CHANGE RTC DATE
Set RTC (Real-time clock) Date
If RTC is installed, this parameter allows you to set the RTC date.
Note • The printer saves the RTC date immediately.
To modify this parameter:
1. Press ENTER.
The printer displays the current RTC date.
2. Modify the values as follows:
• Press the right arrow to move to the next digit position.
• To increase the value, press the up arrow.
• To decrease the value, press the down arrow.
3. Press ENTER to accept the value shown.
Table 15 • Printer Parameters, Password Level 3 (Page 5 of 10)
Parameter Explanation