3.6 TECHNICAL DATA FINISH 250
Voltage : 230 V AC, 50 Hz
Fuses : 16 A time-lag
Unit connecting line : 6 m long, 3 x 1.5 mm
Max. current consumption
hose heating : 4,6 A
Degree of protection : IP 54
Acceptance capacity : 1,1 kW
Max. operating pressure : 25 MPa (250 bar)
Max. volume ow : 2.2 l/min
Volume ow at 12 MPa
(120 bar) with water : 1.8 l/min
Max. temperature of the
coating material : 43 °C
Max. viscosity : 15,000 mPas
Empty weight pump : 28 kg
Hydraulic oil lling
quantity : 0.65 liter
Max. vibration at the spraygun: lower than 2.5 m/s
Max. sound pressure level: 74 dB (A)*
*Place of measurement: 1 m distance from unit and 1.60
m above oor, 12 Mpa (120 bar) operating pressure,
reverberant oor
Voltage : 230 V AC, 50 Hz
Fuses : 16 A time-lag
Unit connecting line : 6 m long, 3 x 1.5 mm
Max. current consumption
hose heating : 6.0 A
Degree of protection : IP 54
Acceptance capacity : 1.3 kW
Max. operating pressure : 25 MPa (250 bar)
Max. volume ow : 2.9 l/min
Volume ow at 12 MPa
(120 bar) with water : 2.3 l/min
Max. temperature of the
coating material : 43 °C
Max. viscosity : 15,000 mPas
Empty weight pump : 29.5 kg
Hydraulic oil lling
quantity : 0.65 liter
Max. vibration at the spraygun: lower than 2.5 m/s
Max. sound pressure level: 74 dB (A)*
*Place of measurement: 1 m distance from unit and 1.60
m above oor, 12 Mpa (120 bar) operating pressure,
reverberant oor