![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/d/ad/dad18232-ec86-475a-ac87-0800a28c5491/dad18232-ec86-475a-ac87-0800a28c5491-bg11.png)
BURNER CLIP
NDERNEATH
MAIN BURNERS
These photos are for reference – it should not be necessary to remove the griddle top to perform the
procedures listed in this manual.
GAS REGULATOR
REGULATOR INSTALLED IN A HORIZONTAL,
UPRIGHT POSITION
The 900RE and AGE series units must
have an exterior machine gas regulator
installed. The units are shipped with a
regulator that has a vent limiter. These
regulators must be installed as close as
possible to the unit in a horizontal, upright
position for optimal performance. They are
adjusted by removing the adjustment cover –
then by turning the adjustment screw to the
right to increase and to the left to decrease.
The regulator and griddle can be damaged
by gas pressures that exceed 14” W.C. or ½
psig.
VENT LIMITER
ADJUSTMENT
COVER
-
17 -