— 10 —
Convection Oven with Electric Ignition (Fig. 3)
SHUT-OFF
VALVE
THERMOSTAT
FAN SWITCH
FAN
PL-53515
Fig. 3
Standard Oven With Standing Pilot (Fig. 2)
SHUT-OFF
VALVE
THERMOSTAT
RED BUTTON
(SAFETY)
PL-53512
Fig. 2
Convection Oven With Standing Pilot
1. Turn Thermostat, Shut-O Valve, and Fan Switch to the OFF position.
2. Wait 5 minutes.
3. Remove lower panel.
4. Depress Red Button on Safety Valve and light Pilot through observation
hole.
5. Hold down Red Button for at least 30 seconds.
6. When Red Button is released, Pilot should remain lit. Pilot flame may be
adjusted with screw on Pilot Adjustment Valve on Pilot supply tubing located
behind Control Panel. There should be only a slight amount of yellow in the
properly adjusted pilot flame.
7. Replace lower panel.
8. Turn the Shut-Off Valve and Fan Switch to the ON position and turn the Thermostat
to the desired temperature.
9. If pilot flame becomes extinguished, repeat above procedure.
10. For a complete shutdown, turn the Thermostat, Shut-Off Valve, and gas shut-off
valve to the OFF position.
1. Turn Thermostat and Shut-Off Valve to the OFF position.
2. Wait 5 minutes.
3. Remove lower panel.
4. Depress Red Button on Safety Valve and light Pilot through observation
hole.
5. Hold down Red Button for at least 30 seconds.
6. When Red Button is released, Pilot should remain lit. Pilot flame may be
adjusted with screw on Pilot Adjustment Valve on Pilot supply tubing located
behind Control Panel. There should be only a slight amount of yellow in the
properly adjusted pilot flame.
7. Replace lower panel.
8. Turn Shut-Off Valve to the ON position and turn the Thermostat to the desired
temperature.
9. If pilot flame becomes extinguished, repeat above procedure.
10. For a complete shutdown, turn the Thermostat, Shut-Off Valve, and gas
shut-off valve to the OFF position.
1. Turn Thermostat and Shut-Off Valve to the OFF position.
2. Wait 5 minutes.
3. Turn Shut-Off Valve to ON position.
4. Turn Fan Switch to ON position.
5. Turn Thermostat to desired setting.
6. Oven burner lights automatically.
7. For a complete shutdown, turn Thermostat, Fan Switch, Shut-Off Valve,
and gas shut-off valve to the OFF position.