Page 15 of 36
4. Remove the pipe nipple and manual gas shut-off valve from the pilot safety valve.
5. Remove any residual tape from the pipe nipples and fittings and coat the threads with
new gas-rated (yellow) Teflon tape.
WARNING: All gas joints disturbed during servicing must be checked for leaks.
Do not use an open flame. Use a hazardous gas tester or a soap and water
solution (Bubbles indicate a gas leak). Failure to comply can cause property
damage, injury or death.
6. Reverse the procedure to install the pilot safety valve.
7. Test the oven to verify proper operation.
Figure 14: C Model Pilot Safety Valve Removal
Manual Gas Shut-Off Valve (C Model)
WARNING: Always perform the Electrical Lockout/Tagout procedure before removing
any sheet metal panels or attempting to service this equipment. Failure to comply with
this procedure can cause property damage, injury or death.
WARNING: Perform the GAS LOCKOUT/TAGOUT procedure before servicing the unit.
1. Perform the SOLENOID, PILOT SAFETY AND GAS SHUT-OFF VALVE ASSEMBLY
removal procedure.
2. Remove the flex line and tee fitting from the bottom of the manual gas shut-off valve.
3. Remove the screw from the bracket securing the manual gas shut-off valve to the gas
mount bracket.
4. Remove the manual gas shut-off valve from the pilot safety valve.
5. Remove any residual tape from the pipe nipples and fittings and coat the threads with
new gas-rated (yellow) Teflon tape.
WARNING: All gas joints disturbed during servicing must be checked for leaks.
Do not use an open flame. Use a hazardous gas tester or a soap and water
solution (Bubbles indicate a gas leak). Failure to comply can cause property
damage, injury or death.
6. Reverse the procedure to install the manual gas shut-off valve.
7. Test the oven to verify proper operation.