VSX SERIES STEAMERS - GENERAL
Page 5 of 80
SPECIFICATIONS
Gas Steamers
INPUT
(BTU/HR)
MANIFOLD
PRESSURE
(INCHES W.C.)
LINE PRESSURE
(INCHES W.C.)
LOAD
(WATTS)
AMPS
(MAX)
NATURAL PROPANE
MAX
MODEL NAT. PROP. NAT. PROP. RECOMMEND MIN RECOMMEND MIN
120V
60HZ
VSX24G 200,000 200,000 4.0 10.0 7.0 5.0 11.0 11.0
14.0
360 3.0
VSX36G
200,000 200,000 4.0 10.0 7.0 5.0 11.0 11.0
360 3.0
240,000 240,000 4.0 10.0 7.0 5.0 11.0 11.0
VSX42GT
200,000 200,000 4.0 10.0 7.0 5.0 11.0 11.0
360 3.0
240,000 240,000 4.0 10.0 7.0 5.0 11.0 11.0
Electric Steamers
AMPERAGE
1 PHASE 3 PHASE 3 PHASE - 4 WIRE
MODEL
TOTAL
KW
208V 240V 208V 240V 480V 220/380V & 240/415V
VSX24E 24* 116 100 67 58 29 34
VSX36E
24* 67 58 29 34
36 100 87 44 50
42 117
48 116 58 67
VSX42ET
24* 67 58 29 34
36 100 87 44 50
*std
Steam Supply
Dry steam must be provided to the steamer. If the steam is heavy with condensate, a Ball Float Trap must be
used in the line and plumbed in before the pressure reducing valve. To ensure rapid heat up of heavy cold loads,
the steam supply line must be sized to maintain pressure as outlined below.
DIRECT STEAM
STEAMERS
(POTABLE)
REGENERATED STEAM
STEAMERS
(*NON-POTABLE)
Supply Pressure 15 psi (max.) 15 psi (max.)
Flow Rate 100 lb. per hour total
(min.)
125 lb. per hour total
(min.)
Pressure Reducing
Valve Output
10 psi (furnished) set accordingly for good
steam generation but no
higher than 15 psi.
(furnished)
*Potable steam is not required for regenerated models but could be used.