A SERVICE OF

logo

ER SERIES FRYER SERVICE MANUAL SUPPLEMENT - REMOVAL AND REPLACEMENT OF PARTS
F24696 (May 2001) Page 6 of 56
REMOVAL AND REPLACEMENT OF PARTS
COVERS AND PANELS
WARNING:
DISCONNECT THE ELECTRICAL
POWER TO THE MACHINE AT THE MAIN
CIRCUIT BOX. THERE ARE SEVERAL SEPARATE
CIRCUITS. BE SURE ALL ARE DISCONNECTED.
PLACE A TAG ON THE CIRCUIT BOX(ES)
INDICATING THE CIRCUIT IS BEING SERVICED.
Front Control Panel
1. Open the cabinet door to the fryer section being
serviced.
2. Remove the screws along the bottom lip and
along the top of the of the control panel.
3. Work the panel loose at each end and lift off.
4. Reverse procedure to install.
Basket lift Covers
1. Loosen bolt at the top of each basket lift hanger
and lift the basket hangers from the support rod.
2. Remove the screws that secure the lower cover
at the rear of the fryer section.
3. Remove the screws along each side of the
cover.
4. Lift the cover and place to the side.
5. Reverse procedure to install.
PUMP AND MOTOR
WARNING:
DISCONNECT THE ELECTRICAL
POWER TO THE MACHINE AT THE MAIN
CIRCUIT BOX. THERE ARE SEVERAL SEPARATE
CIRCUITS. BE SURE ALL ARE DISCONNECTED.
PLACE A TAG ON THE CIRCUIT BOX(ES)
INDICATING THE CIRCUIT IS BEING SERVICED.
NOTE
: Refer to component location picture 6100 for
location of pump motor.
1. Open the right side cabinet door of the filter
section.
2. Pull the filter drawer out, remove the filter tank
assembly and push the tank support arms back
underneath the fryer.
3. Disconnect the electrical connection to the
motor.
NOTE
: The remaining steps are written for front
removal of the pump assembly. If access to the
back of the fryer is available, it may be easier to
remove the pump from the rear.
4. Separate the swivel hose connection on the right
side (intake) of the pump.
5. Separate the swivel hose connection on the left
side (discharge) of the pump.
6. Remove the mounting bolts from the motor.
7. Remove the motor, pump and piping assembly.
A. If replacing the pump and motor, remove
the existing piping assemblies and reuse.
8. Reverse procedure to install.
NOTE
: Ensure the rubber vibration pad or the
grommets are installed under the motor mounting
plate.