RS-232C Communication (continued)
NOTE • Operation cannot be guaranteed when the projector receives an
undened command or data.
• Provide an interval of at least 40ms between the response code and any
other code.
• The projector outputs test data when the power supply is switched ON, and
when the lamp is lit. Ignore this data.
• Commands are not accepted during warm-up.

("h" shows hexadecimal)

When the projector receives the Set, Increment, Decrement or Execute
command correctly, the projector changes the setting data for the specied
item by [Type], and it returns the code.

When the projector cannot understand the received command, the projector
returns the error code.
In such a case, check the sending code and send the same command again.

When the projector cannot execute the received command for any reasons,
the projector returns the error code.
In such a case, check the sending code and the setting status of the projector.

When the projector receives the GET command correctly, the projector returns
the responce code and 2 bytes of data.