Electrical
System
Reelmaster 6500-D/6700-D
Page 5 - 11
Electrical System (Rev. C)
1. Overlay decal (English shown)
2. “Inputs Displayed” LED (Red)
3. “Outputs Displayed” LED (Green)
4. Toggle button
1
Diagnostic ACE Display Functions
Figure 13
3
2
4
3
2
1
7
1. LED lit if oil level is too high
2. LED lit if oil level is OK
3. LED lit if oil level is too low
4. LED lit if slow leak detected
5. Target oil level - Cold oil & c utting units
raised
6. One or two LED’s lit displaying
relative position of the Turfdefender’s
internal float
(any combination of 3, 3 or 4, or 4)
7. “Inputs Displayed” LED “ON” (Red)
Normal Operation:
a. “Oil Level OK” LED lit
b. 1 or 2 LED’s lit on left column
Using “Inputs Displayed” (Red Text)
4
6
a.
b.
Figure 14
5
Normal Operation:
a. “Valve ON” LED lit steadily
b. “Self Diagnostic” LED lit steadily
c. “DATA LINE” LED lit steadily
d. “Alarm ON” LED lit temporarily
Using “Outputs Displayed” (Green Text)
Problem Diagnosed:
The appropriate LED will blink to
identify the problem
Figure 15