A SERVICE OF

logo

Burner adjustments must be performed by a
qualified technician. Improper adjustments
may cause harmful by-products or void the
appliance’s warranty.
Allow burners to cool before attempting to re
-
move them!
WARNING
Step 7: Burner Test and Adjustment
Flame Adjustment (if necessary):
Tube-style gas burners used in Thermador©
appliances have air shutter systems which are
similar to the illustration in Figure 14, and can be
adjusted using the following method (unless ad
-
justment is not recommended). It is necessary to
remove the burner from the appliance in order to
perform air-shutter adjustments.
Loosen shutter screw(s) and turn shutter to
new position.
Adjust the shutter to more-closed position if
the flame is lifting or blowing, or is not carry-
ing over.
Adjust the shutter to more-open position if
the flame is too yellow. (See Figure 14.)
Retighten the shutter screw(s).
After adjustment, reinstall the burner and
perform flame evaluation. The air shutter
must fit over the orifice hood for proper opera
-
tion of the burner.
Repeat procedure as needed until flame char
-
acteristics are acceptable. (See Figure 13.)
Call Thermador® if:
1. Any of the burners do not light.
2. Any of the burners continue to burn
yellow.
Air Shutter Adjustment (if necessary)
Air
Shutter
Screw
More Open:
Less Yellow Flame
More Closed:
Less Blue Flame
More Carryover
Less Lifting or Blowing
FIG. 14
14