31
GB
The remaining charge indicator is incorrect.
• This phenomenon occurs when you use the camera in an extremely hot or cold location.
• A discrepancy arose between the remaining charge indicator and the actual remaining battery
charge. Fully discharge the battery pack once, then charge it to correct the indication.
• The battery pack is discharged. Insert the charged battery pack (page 10).
• The battery pack is dead. Replace it with a new one.
Cannot charge the battery pack.
• You cannot charge the battery pack using the AC Adapter (sold separately).
The CHARGE lamp flashes while charging the battery pack.
• Remove the battery pack being charged, and then insert the same battery pack into the battery
charger securely again.
• The temperature may be outside of the recommended operating temperature. Charge the battery pack
in an recommended ambient temperature of between 10 to 30°C (50 to 86°F) (BC-CSKA only).
Cannot record images.
• Check the free capacity of the internal memory or “Memory Stick Duo” media (pages 28, 29).
If it is full, do one of the following:
– Delete unnecessary images (page 17).
– Change the “Memory Stick Duo” media.
• You cannot record images while charging the flash.
• When shooting a still image, set the mode dial to a position other than .
• Set the mode dial to when shooting movies.
Vertical streaks appear when you are shooting a very bright subject.
• The smear phenomenon is occurring and white, black, red, purple, or other streaks appear on
the image. This phenomenon is not a malfunction.
Cannot play back images.
• Press the (Playback) button (page 17).
• The folder/file name has been changed on your computer.
• Sony does not guarantee playback of image files on the camera if the files have been
processed using a computer or recorded with another camera.
• The camera is in USB mode. Delete the USB connection.