Step 4: Customizing Your Thermostat
◆ Set Time of Day, Day of Week,
Temperature Differential,
Residual Cooling
1. Press SET and PROG/MAN.
Release simultaneously.
Press or to change time of day.
2. Press Press
to change day of week.
3. Press Press
to change 1st stage
temperature differential.
NOTE: THE TEMPERATURE DIFFERENTIAL IS FACTORY PRESET AT 1°. THIS MEANS THAT
WHENEVER THE ROOM TEMPERATURE CHANGES BY ONE FULL DEGREE FROM THE TEMPERA
-
TURE SETTING
, THE SYSTEM WILL TURN ON. IF THE SYSTEM TURNS ON TOO OFTEN,
INCREASE THE TEMPERATURE DIFFERENTIAL.
4. Press Press
to change 2nd stage
temperature differential.
NOTE: THE SECOND STAGE TEMPERATURE DIFFERENTIAL IS FACTORY PRESET AT 2°.
5. Press Press
to change
residual cooling.
NOTE: THE RESIDUAL COOL FEATURE WILL KEEP THE SYSTEM FAN ON FOR AN
ADDITIONAL
30, 60, OR 90 SECONDS AFTER THE COMPRESSOR CYCLES OFF IN COOL
MODE
. THE RESIDUAL COOL FEATURE CAN BE SET ONLY IN THE COOL MODE.
8
>
>