IMPORTANT SAFETY INFORMATION
WARNING:
•Always turn off power at the main power source by unscrewing fuse
or switching circuit breaker to the off position before installing,
removing, cleaning, or servicing thermostat.
Read all the information in this manual before installing or program-
ming this thermostat.
This is a 24 VAC low-voltage thermostat. Do not install on voltages
higher than 30 VAC.
All wiring must conform to local and national building and electrical
codes and ordinances.
Do not short (jumper) across terminals on the gas valve or at the
system control to test installation. This will damage the thermostat
and void the warranty.
Step 1: Replacing Existing Thermostat
1. Turn off power to heating and cooling system.
2. Remove cover from old thermostat to expose wires (Figure 1).
3. Disconnect wires one at a time from existing terminals. Use enclosed labels
to mark existing wires. Refer to cross references in Table 1 if existing wiring
does not directly match the labels.
Old Terminal New Label Description
R, V-VR or VR-R R 24 VAC, Return
Y, Y1 or M Y Cooling Control
O or R O Cool Active Reversing Valve
BBHeat Active Reversing Valve
F or G G Fan Control Relay
C, X or B C 24 VAC, Transformer Common Side
W1 or W W Heating Control
NOTE: THIS THERMOSTAT REQUIRES A 24V COMMON WIRE FOR PROPER OPERATION.