33
3. Leaving enough wire for the LEAD IN, insert the
specified number of turns of wire in the cut grooves.
(See chart).
CAUTION: Be careful not to damage the wire
insulation during installation.
4. After completing the required number of loop turns,
twist the ends together at the rate of 6 turns per foot to
form the LEAD-IN.
5. Seal the LEAD-IN wire in the conduit to prevent
moisture seepage into the conduit.
6. Fill over the loop wires in the groove with a
recommended loop sealant. Contact your distributor
for available sealants.
7. Mount the loop detector in the operator and connect
the wire loop.
8. Connect loop detector to the control board as shown
on the following page.