
35
Technical information
Technical information
Factory settings
The table displays the factory values (F value) of the
settings that you, as a customer, (K) can change via the
customer menus Menu and Advanced menu.
Read the table as follows:
To fi nd the settings for Holiday go to the Advanced menu,
select Temperature, then select Time limited settings and
then Holiday.
Menu
Level
F value
Temperature increase/decrease
K
= (no change)
Room temperature setting
K 20ºC
Extra hot water
K0 h
Advanced menu
Level
F value
Temperature
Heating system temperature
----"----\Heat curve K
V=20,0ºC
H=55,2ºC
----"----\Hysteresis
----"----\----"----\Maximum K 16ºC
----"----\----"----\Minimum K 4ºC
----"----\----"----\Time factor K 10
Room sensor settings (T5)
----"----\Room temperature setting K 20ºC
----"----\Room sensor infl uence
----"----\----"----\Change factor K 5
----"----\----"----\Blocking time K 4 h
Time limited settings
----"----\Time control heating K Off
----"----\----"----\Day and time K
----"----\----"----\Change in temperature K -10ºC
----"----\Holiday K Off
----"----\----"----\Date K
----"----\----"----\Change in temperature K -10ºC
Heating season
----"----\Heating season limit K 18ºC
----"----\Delay K 4 h
----"----\Direct start limit K 10ºC
Heating, maximum operating time at hot
water requirement
K 20 min
Advanced menu
Level
F value
Hot water (T3)
Extra hot water
----"----\Number of hours K 0
----"----\Stop temperature K 65ºC
Hot water peak
----"----\ Interval K 0 days
----"----\Start time K 03:00
Time control hot water K Off
Setting the clock
Set date K
Set time K
Alarm
Alarm log
----"----\Delete alarm log? K No
Access level
K0
Return to factory settings
KNo
Deactivate alarm buzzer
KNo
Program version
K xx.xx.x