CALL LIMITER
◆ The factory setting for the call limiter is OFF.
This allows the communicator to report
burglary alarms, once for each sensor, as
many times as they are triggered.
◆ Optionally, the Console can be programmed
to only allow five burglary reports total per
arming period.
✍
NOTE: Sensors programmed to 24-hour zones
(Emergency, Panic, Fire) always send a Central
Station Report and always sound the local siren
regardless of the Call Limiter setting.
DIALING DELAY
◆ The factory setting will cause the
communicator to dial the Central Station
instantly when an alarm or supervisory event
occurs.
◆ Alternately, the communicator can be
programmed to wait 30 seconds before
dialing. This gives the user time to disarm the
system and prevent communications in the
case of a subscriber generated false alarm.
DIALING METHOD
◆
The factory setting causes the communicator
to dial using DTMF (dual-tone
multi-frequency) tone dialing.
◆ Alternately, the communicator can be
programmed to use pulse (rotary) dialing. Use
this option if the telephone line in the
installation does not support tone dialing.
0
1
HOME
AWAY
0 FOR OFF (UNLIMITED)
1 FOR ON (5 VIOLATIONS)
PROGRAMMING STEP #101
PROGRAM
STORE PROGRAM
1
0 = FOR 0 SECOND DELAY
1 = FOR 30 SECOND DELAY
PROGRAMMING STEP #103
PROGRAM
STORE PROGRAM
0
4
GHI
HOME
AWAY
0 FOR TONE DIALING
1 FOR PULSE DAILING
PROGRAMMING STEP #104
PROGRAM
STORE PROGRAM
1