CALL LIMITER
The factory setting for the call limiter is OFF.
This allows the communicator to report
burglary alarms, once for each sensor, as
many times as they are triggered.
Optionally, the Console can be programmed
to only allow five burglary reports total per
arming period.
NOTE: Sensors programmed to 24-hour zones
(Emergency, Panic, Fire) always send a Central
Station Report and always sound the local siren
regardless of the Call Limiter setting.
DIALING DELAY
The factory setting will cause the
communicator to dial the Central Station
instantly when an alarm or supervisory event
occurs.
Alternately, the communicator can be
programmed to wait 30 seconds before
dialing. This gives the user time to disarm the
system and prevent communications in the
case of a subscriber generated false alarm.
DIALING METHOD
The factory setting causes the communicator
to dial using DTMF (dual-tone
multi-frequency) tone dialing.
Alternately, the communicator can be
programmed to use pulse (rotary) dialing. Use
this option if the telephone line in the
installation does not support tone dialing.
0
1
HOME
AWAY
0 FOR OFF (UNLIMITED)
1 FOR ON (5 VIOLATIONS)
PROGRAMMING STEP #101
PROGRAM
STORE PROGRAM
1
0 = FOR 0 SECOND DELAY
1 = FOR 30 SECOND DELAY
PROGRAMMING STEP #103
PROGRAM
STORE PROGRAM
0
4
GHI
HOME
AWAY
0 FOR TONE DIALING
1 FOR PULSE DAILING
PROGRAMMING STEP #104
PROGRAM
STORE PROGRAM
1