TK-480/481
LEVEL DIAGRAM (TK-481)
VCO
IC14
*
C131
PLL
Q10
C136
Q17
C193
Q11
D5
C149
Q12
C152
Power
module
D7 C169
L30
ANT
2.5W
10.2dBm
(Q10 open)
7.4dBm
(Q17 open)
0.4dBm
(D5 open)
+5.3dBm
(Q12 open)
+17.8dBm
(C152 open)
RF (899.00MHz)
EMC
MIC
12
LPF
ALC
COMP
SW
IDC
6
DAC
I5
O5
DAC
I2
O2
13
15 16
18
19
9
8
IC12
16.1mVrms
16.7mVrms 41.2mVrms 353mVrms 338mVrms
318mVrms
IC4 IC3 (1/2) IC4
*
530mVrms 133mVrms 109mVrms 54mVrms
AF
5
43
41
DAC
*
IC12
C58
IC3
IC4
AF
AMP
IC300
SP
500mW
(BTL)
188mVrms 254mVrms 376mVrms 132mVrms 29mVrms
AF
C169
L30
ANT
C143
L11
C139
Q9 C122
L20
C110
Q6
R60
XF1
R51
Q5
C55
FM IF
SYSTEM
CF1,2
IC8
AMP
*
118.0dBm 118.4dBm 118.4dBm 118.0dBm 108.3dBm 106.6dBm 105.5dBm 117.0dBm
107.5dBm
(C55 open)
115mVrms 268mVrms
58dBm 55dBm
RF (938.00MHz)
IF1 (44.85MHz)
IF2
(455kHz)
AF
To make measurements in the AF section,
connect the oscilloscope proves directly.
(ANT input : 47dBm, 1kHz FM, 1.5kHz dev.)
In the RF section, use a 1000pF coupling capacitor.
(The display shows the SSG input value required
to obtain 12dB SINAD.)
AG is set to the MIC input
becomes 1.5kHz Dev at 1kHz MOD.
To make measurements in the
AF section, connect the
oscilloscope proves directly.
In the RF section, use a 1000pF
coupling capacitor.
RX Section
TX Section