Weight 6.17 oz (175g)
Operating environment Indoors
Operating temperature range 32° to 104° F (0° to 40° C)
Operating humidity range 0-90% relative humidity
Storage temperature range -4° o to 158° F (-20° to 70° C)
Electrical
Voltage 100VAC to 240VAC
RF Frequency
US
915 MHz
EU
869 MHz
AUS/NZ 921 MHz
Electrical Frequency 50/60Hz auto detected at power-up
Load type(s)
Resistive
Inductive/capacitive
Low voltage halogen
Maximum load
US
15A 240VAC
EU
16A 240VAC
AUS/NZ 10A 240VAC
3600W/240VAC Resistive
700W/240VAC Inductive/Capacitive
2000W/240VAC Bulbs/Low Voltage Halogen
Minimum load None
User replaceable fuse
US
16A, 5x20mm slow blow/burn glass fuse
EU
No user replaceable fuse
AUS/NZ
Hardwired remote control Yes, either latching or momentary switches supported
Retains all settings without power Yes, saved in non-volatile EEPROM
Standby power consumption < 1 watt
Safety approval(s) ETL, CE, C-Tick
Certifications
FCC 15.107, 15.109, 15.249
RSS 210
EN 300 220-2, 301 489-3
AS/NZS 4268, CISPR 22
UL 1472
IEC 60669-2-1
FCC ID SBPDR01
Troubleshooting
Problem
Possible Cause
Solution
The LED on DIN Rail is
not turning on at all and
won't control my light
DIN Rail is not getting power
Make sure the circuit breaker is turned on
Check junction box wires to ensure all connections are
tight and no bare wires are exposed
Check the light fixture to ensure all connections are tight
and no bare wires are exposed