MENU FUNCTIONS
In general a long delay time decreases the risk of tracks
forming (the robotic lawnmower will nd the charging
station more often through irregular searches) but gives
longer search times. A short delay time gives the opposite
effect, i.e. short search times with increased risk of tracks
forming along the guide wires and/or boundary wires.
Guide
Make sure the Follow guide home checkbox is activated.
Otherwise use the down arrow key to select the checkbox
and then press OK.
Use the number keys to enter the delay time.
Automower® 320 has only Guide.
Guide > Guide 1 delay
Move the cursor to Guide 1 delay and enter the delay
time in minutes.
The delay time is normally specied as a gure between
0 and 10 minutes.
Guide > Guide 2 delay
Not applicable for Automower® 320.
Move the cursor to Guide 2 delay and enter the delay
time in minutes.
Boundary loop
Make sure the Follow boundary home checkbox is
activated. Otherwise use the down arrow key to select the
checkbox and then press OK.
Use the number keys to enter the delay time.
Move the cursor to Boundary delay and enter the delay
time in minutes.
This time is normally longer than for Guide 1 and Guide 2
as it is normally better if the robotic lawnmower follows
one of the guide wires home to the charging station.
The delay time is normally specied as a gure between
10 and 20 minutes but can be shorter if a guide wire is not
installed and it is unlikely that the robotic lawnmower can
nd the charging station through an irregular search.
If the robotic lawnmower passes a guide wire while
following the boundary wire, it will stop searching along
the boundary wire and instead start to follow the guide
wire into the charging station.
If it is strictly inappropriate in the installation to follow the
boundary loop, the Follow boundary home checkbox has
to be deactivated.