Menu Driven Display
2 Heat / 2 Cool
Terminal Designations
Specifications
Electrical rating: 24 Volt AC (18-30 VAC)
1 amp maximum load per terminal (relay outputs)
4 amp total maximum load (all terminals combined)
Temperature control range: 45˚- 90˚F (7˚- 32˚C)
Accuracy: +/-1.0˚F (+/-0.5˚C)
Power Source: 24 VAC
Auto Changeover deadband: Selectable 2˚ to 8˚F
Temporary temperature override: 3 hour maximum or next setpoint
Remote sensor capable: 1 indoor and 1 outdoor sensor
System configurations: Multi-stage heat pumps
Terminations: R, E, Y1, B, W2, Y2, L, O, G, C, IS, OS, H
Other Multi-Stage
Heat Pump Thermostats
9720i: Programmable, 7 Day
9620: Programmable, 7 Day
9420: Non-Programmable
Shipping Information
Indiv. Ctn. Dim.: 6.625" x 4.25" x 1.625"
Master Ctn. Qty.: 6
Master Ctn. Dim.: 9.25" x 5.625" x 7.5"
Master Ctn. Cu. Ft.: .23
Master Ctn. Wt.: 3.5 lbs.
Max. Pallet Qty.: 1260
Max. Pallet Wt.: 785 lbs.
Optional Sensors:
REMOTE INDOOR
REMOTE OUTDOOR
Distributed by:
Item 9020i and 9025i Remote Sensors
Indiv. Ctn. Dim.: 2.625" x 1.5625" x 4.4375"
Master Ctn. Qty.: 6
Master Ctn. Dim.: 5.625" x 5.125" x 5.125"
Master Ctn. Cu. Ft.: .09
Master Ctn. Wt.: .78 lbs.
H
HEAT PUMP
DELUXE
PROGRAMMABLE
THERMOSTAT
9820
i
Climate Controls Americas
515 South Promenade Avenue
Corona California 92879-1736 USA
Telephone +1 800 304 6563 Facsimile +1 800 426 0804
Outside the USA +1 630 260 3402
Patents Pending www.icca.invensys.com
©2003 Climate Controls Americas 8/03 - #150-1709
Feature Comparison
Robertshaw Honeywell, Inc. Carrier Corp.
9820i PC8900 THERMIDISTAT
Manual Override X X X
EEPROM X X X
Compressor Short Cycle Protection X X X
7 Day Programming X X X
Resume X X X
Auto Changeover X X X
Line Powered X X X
Programmable Fan X X X
O & B Terminals X X Partial
˚F and ˚C X X X
Status Indicators X X X
Adjustable Differential X X X
Gas/Electric X X X
Energy Efficient Recovery X X X
Manual Humidity Control X X X
Automatic Humidity Control
based on Outdoor Temperature
XX X
Pre-Set Program X X X
4 Hour Reserve X X X
Events / day 2, 4, 6 4 4
Hidden Service Level X X X
Remote Outdoor Sensor X X X
Security Key Pad X X X
Vacation Setting X X X
Air Filter Monitor X X X
12 or 24 Hour X X
Condensation Control X X
Remote Indoor Sensor X X
Large Display X X
Back Lighting X X
Service Interval Reminders X
5/2 Day Programming X
Adjustable Residual Cooling X
1/2 Degree Resolution X
Menu Driven (Ease of Programming) X
24 Hr. Programming X
All marks shown are the property of their respective owners.