Problem Problem cause solution
Pilot will not light Gas valve may be
OFF
Turn the gas valve ON
Tank fuel empty Refill LP gas tank
Air in supply system Purge air from lines
Loose connection Check all fittings
Pilot will not stay on Debris around pilot Clean dirty area
Loose connection Tighten connection
Thermocouple bad Replace thermocouple
Gas leak in line Check connections
Lack of fuel pressure
Fuel tank is near empty
Burner will not light Pressure is low Fuel tank is near empty
Control valve not ON
Turn valve to ON
Thermocouple bad Replace thermocouple
Pilot light assembly
bent or not in correct
location
Place pilot in proper
Position and retry
Burner flame goes
off immediately
after ignition
Low gas pressure Let the pilot flame stay lit
for 10 minutes before
setting variable knob to
“LO”