3-3
SW8/12 VGA Ars • Control
Error responses
When the switcher receives a valid command, it executes the command and sends
a response to the host device. If the unit is unable to execute the command because
the command contains invalid parameters, it returns an error response to the host.
Error response codes are:
E01—Invalidinputchannelnumber(outofrange)
E06—Invalidinputchannelchange(auto-switchmodeactive)
E09—Invalidfunction(mode)parameter
E10—Invalidcommand
E13 — Invalid value (out of range)
Timeout
Apauseof10secondsorlongerbetweencommandASCIIcharactersresultsina
timeout. The command operation is aborted with no other indication.
Using the command/response table
Thecommand/responsetableisonthefollowingpages.Lowercaselettersare
allowed in the command field only as indicated. Symbols are used throughout
thetabletorepresentvariablesinthecommand/responseelds.Commandand
responseexamplesareshownthroughoutthetable.TheASCIItoHEXconversion
tablebelowisforusewiththecommand/responsetable.
ASCII to HEX Conversion Table
Space
Figure 3-1 — ASCII-to-HEX conversion table
Symbol definitions
]
=CR/LF(carriagereturn/linefeed)
}
= Carriage return (no line feed)
•
= Space character
X!
=Inputnumber SW8=0through8
SW12=0through12
0=outputmute
X@
=Indicatessignalpresence 0=signalnotpresent
1 = signal is present
X#
=On/offstatus 0=off
1 = on
X$
=Volumevalue/range 0-100
X%
= Switch mode 1 = normal mode
2 = auto switch mode