General Specifications
Diode Test Bias voltage: 2.8VDC typical
Continuity Check Audible signal will sound if the resistance is less than 100
Input Impedance 1MΩ (VDC & VAC)
AC Bandwidth 50 / 60Hz
Display 2000 count (0 to 1999) LCD
Overrange indication “1___” is displayed
Polarity Automatic (no indication for positive); Minus (-) sign for negative
Measurement Rate 2 times per second, nominal
Low Battery Indication “
” is displayed
Battery One (1) 9V battery (NEDA 1604)
Fuses mA range; 200mA/250V ceramic fast blow (5x20mm)
A range; 10A/250V ceramic fast blow (5x20mm)
Operating Temperature 32ºF to 122ºF (0ºC to 50ºC)
Storage Temperature -4
o
F to 140
o
F (-20
o
C to 60
o
C)
Operating Humidity Max 70% up to 87ºF (31ºC) decreasing linearly to 50% at 122ºF (50ºC)
Storage Humidity < 80% RH
Operating Altitude 7000 ft. (2000 meters) maximum.
Weight 9.17 oz (255g)
Size 5.2” x 2.6” x 1.5” (132 x 66 x 38mm)
Approvals CE, ETL
Safety
This meter is intended for indoor use and protected, against the users,
by double insulation per EN61010-1 and IEC61010-1 2nd Edition
(2001) to CAT III 600V; Pollution Degree 2. The meter also meets UL
61010-1, Second Edition (2004), CAN/CSA C22.2 No. 61010-1, Second
Edition (2004), and UL 61010B-2-031, First Edition (2003)
PER IEC1010 OVERVOLTAGE INSTALLATION CATEGORY
OVERVOLTAGE CATEGORY I
Equipment of OVERVOLTAGE CATEGORY I is equipment for connection to circuits in which
measures are taken to limit the transient overvoltages to an appropriate low level. Note – Examples
include protected electronic circuits.
OVERVOLTAGE CATEGORY II
Equipment of OVERVOLTAGE CATEGORY II is energy-consuming equipment to be supplied from
the fixed installation.
Note – Examples include household, office, and laboratory appliances.
OVERVOLTAGE CATEGORY III
Equipment of OVERVOLTAGE CATEGORY III is equipment in fixed installations.
Note – Examples include switches in the fixed installation and some equipment for industrial use
with permanent connection to the fixed installation.
OVERVOLTAGE CATEGORY IV
Equipment of OVERVOLTAGE CATEGORY IV is for use at the origin of the installation.
Note – Examples include electricity meters and primary over-current protection equipment