![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/5/37/537819fa-1653-4823-b384-199e8c02924b/537819fa-1653-4823-b384-199e8c02924b-bg5.png)
42500-EU-EN v2.0 10/13
5
Specifications
Infrared Thermometer Specifications
Range / Resolution -4 to 500
o
F (-20 to 260
o
C) 1
o
F/C
Accuracy ± 2% of reading or ±4
o
F (2
o
C) whichever is greater, from 60 to
113
o
F (15 to 50
o
C)
± 3% of reading or ±6
o
F (3
o
C) whichever is greater, for remainder
of range: -4 to 500
o
F( -20 to 260
o
C)
Note: Accuracy is specified for the following ambient temperature
range: 64 to 82°F (18 to 28°C)
Emissivity 0.95 fixed value
Field of View D/S = Approx. 6:1 ratio (D = distance, S = spot)
Laser power Less than 1mW
Spectral response
6 to 14 m (wavelength)
General Specifications
Display 1999 count, backlit LCD display with function indicators
Display rate 1 second approx.
Operating Temperature 32°F to 122°F (0°C to 50°C)
Operating Humidity Max. 80% RH
Power Supply 9V battery
Automatic Power Off Meter shuts off automatically after 6 seconds
Weight 4.9 oz. (140g)
Dimensions 6.7 x 1.7 x 1.6” (170 x 44 x 40mm)
Copyright©2013FLIRSystems,Inc.
Allrightsreservedincludingtherightofreproductioninwholeorinpartinanyform
www.extech.com