![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/4/b6/4b60aa07-5093-4535-9dee-a7b1d12e6589/4b60aa07-5093-4535-9dee-a7b1d12e6589-bg2f.png)
Rev. C Product Specifications of the TM-C100 A-1
TM-C100 Technical Reference Guide
Appendix A
Product Specifications of the TM-C100
A.1 Product Specifications
Item Specification
Interface (compatible) USB
Power supply Power supply with a dedicated AC adapter
Input voltage (rated) Input voltage (rated) 90 (100 - 10%) to 264 (230 + 15%) VAC
Frequency (rated) 47 to 63 Hz
Power consumption Operating
Idling
Average: Approximately 11 W
Peak: Approximately 13 W
Average: Approximately 1 W
Applicable standards Europe: CE marking EMC Directive: 89/336/EEC
EN55022 Class B
EN55024
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-5
IEC61000-4-6
IEC61000-4-11
Safety standard: TÜV (EN 60950)
North
America:
EMI: FCC/ICES-003 Class A
Safety Standard: UL 60950/CSA C22.2 No. 60950
Oceania: EMC: AS/NZS 3548/CISPR22 Class B
Japan: EMI: VCCI Class A
Reliability Product
lifetime:
Mechanism 12,000,000 passes (6,000,000 carriage returns)
Print head 1,600,000,000 shots/nozzle
(Shots are the numbers of pulses energized for the print
head.)
Autocutter Plain paper, special fine paper 350,000 cuts
Special matte paper, plain borderless label paper
200,000 cuts
ASF 200,000 sheets
(The end of product lifetime is when the printer reaches
the start of the wear-out failure period.)
MTBF 180,000 hours (Failure is defined as a random failure occurring during the random
failure period.)
MCBF 30,000,000 passes
This is an average failure interval based on failures relating to wearout and random
failures up to the life of 12,000,000 passes.
Temperature and humidity Printing:
Storage:
10 to 35ºC, 20 to 80% RH no condensation
Packaged for shipping
–20 to 60ºC, 5 to 85% RH no condensation
(Ink not loaded)
(within 120 hours at
–20ºC or 60ºC)
Ink loaded
–20 to 40ºC, 20 to 85% RH
Absolute maximum rated
temperature
70ºC (This temperature must NOT be exceeded whenever it is operating or in
storage.)
Pressure (elevation) Printing:
Operating:
775 to 1,050 hPa (corresponding to 0 to 2,000 m above sea level)
700 to 1,060 hPa (corresponding to 0 to 2,500 m above sea level)