A SERVICE OF

logo

-8 IGX 8 Installation Manual, Release 8.2.0
E3 Interface
Line Rate: 34.368 Mbps ± 20 ppm, asynchronous.
Line Code: HDB3.
Clock Source Mode: Internal (Asynchronous).
Signal Level: ITU-T G.703
Framing Formats: ITU-T G.804, G.832,
Alarms Processed: AIS.
LOS.
Remote Alarm Indication.
Loss Of Framing.
Line Errors Counted: BPV.
Parity Bit Errors.
Receiver Input Impedance: 75 ohms unbalanced.
Transmission Modes: Point-to-Point or Drop and Insert.
Jitter: per ITU-T G.823.
Connector: 75 ohm BNC.
Max. Line Lengths: 137 meters (450 ft.) using specified cable.
Indicators: RED Alarm.
YELLOW Alarm.
LOS.
AIS.