A SERVICE OF

logo

Security Escort | Technical Reference Manual | 7.0 Importing a
Subscriber Database
EN | 78
Bosch Security Systems | 6/12 | 38947D
Table 1: continued
Data Fields in
Required Order
Excel
Column
Restrictions
Build Code
AC
0 Medium, 1 Slim, 2 Large. This field should contain only numeric
ASCII characters.
Hair Color
AD
0 Brown, 1 Auburn, 2 Black, 3 Blond, 4 Brunet, 5 Grey, 6 Red. This
field should contain only numeric ASCII characters.
Eye Color
AE
0 Brown, 1 Blue, 2 Green, 3 Hazel, 4 Grey. This field should contain
only numeric ASCII characters.
Pager Group A
AF
0-99, This field should contain only numeric ASCII characters.
Pager Group B
AG
0-99, This field should contain only numeric ASCII characters.
Pager Group C
AH
0-99, This field may contain only numeric ASCII characters.
Fixed Floor
Level
AI
0 Basement5, 1 Basement4, 2 Basement3, 3 Basement2, 4 Basement1, 5
Tunnel, 6 Basement, 7 Ground, 8 Outside, 9 Floor 1, 10 Floor 2, 11
Floor 3, 12 Floor 4, 13 Floor 5, 14 Floor 6, 15 Floor 7, 16 Floor 8,
17 Floor 9, 18 Floor 10, 19 Floor 11, 20 Floor 12, 21 Floor 13, 22
Floor 14, 23 Floor 15, 24 Floor 16, 25 Floor 17, 26 Floor 18, 27
Floor 19, 28 Floor 20, 29 Floor 21, 30 Floor 22, 31 Floor 23, 32
Floor 24, 33 Floor 25, 34 Floor 26, 35 Floor 27, 36 Floor 28, 37
Floor 29, 38 Floor 30, 39 Floor 31, 40 Floor 32, 41 Floor 33, 42
Floor 34, 43 Floor 35, 44 Floor 36, 45 Floor 37, 46 Floor 38, 47
Floor 39. This field should contain only numeric ASCII characters.
Fixed Map X
Location
AJ
This field can contain only numeric ASCII characters.
Fixed Map Y
Location
AK
This field can contain only numeric ASCII characters.
Fixed Bitmap
Number
AL
0-99 This field can contain only numeric ASCII characters.
Supervision
Interval
AM
0 None, 1 is 90 Second Supervision, 2 is 30 Second Supervision, 3 is
1 Hour Supervision. This field can contain only numeric ASCII
characters.
Alarm Group
AN
0-99, This field can contain only numeric ASCII characters.
Shorted Loop
AO
This field can contain only numeric ASCII characters.
Open Loop
AP
This field can contain only numeric ASCII characters.
Status
AQ
Encoded value. Do not change.
Enable Magnetic
Reed
AR
This field can contain only numeric ASCII characters.
Fixed Location
Text
AS
This field can be up to 254 characters. This field can contain any
printable ASCII character except the “?”.
Magnetic Reed
Text
AT
This field can be up to 30 characters. This field can contain any
printable ASCII character except the “?”.
Shorted Loop
Text
AU
This field can be up to 30 characters. This field can contain any
printable ASCII character except the “?”.’
Open Loop Text
AV
This field can be up to 30 characters. This field can contain any
printable ASCII character except the “?”.
Status Flags
AW
Encoded value. Do not change.
Modify Op
AX
0-30000, this field can contain only numeric ASCII characters.
Test Time
AY
Encoded 32-bit time value. Do not change.
Last Transmitter
Change
AZ
Encoded 32-bit time value. Do not change.
Spare Date
BA
Encoded 32-bit time value. Do not change.
Last Fail To
Test Letter
BB
Encoded 32-bit time value. Do not change.
Created
BC
Encoded 32-bit time value. Do not change.
Modified
BD
Encoded 32-bit time value. Do not change.
Low Battery
BE
Encoded 32-bit time value. Do not change.
Spare2
BF
This field should be blank.
Spare3
BG
This field should be blank.
Spare4
BH
This field should be blank.
Spare5
BI
This field should be blank.
Number Of Tests
BJ
This field may contain only numeric ASCII characters.