Adjustment Normal 16/Super 16
50
• Mount the alignment screw SW 1,5 (wrench
width 1,5 mm) top right.
• Remove stop plate segment and locking knob
after removing the fastening intermediate rings
and refasten on the opposite side.
• Replace the 6 cylinder head screws and screw tight.
• Check viewing screen for focus.
• Check flange focal distance.
Changing the Fibre Optic Viewing Screen
• For changing the fibre optic viewing screen see
chapter 5.
Adjusting the Opening in the Universal Film
Gate
For Normal 16 part of the film gate is covered by a rail
which is removed when changing to Super 16.
• Unscrew the 6 screws on the cover plate
.
• Remove the cover plate .
• Unscrew the 8 cylinder head screws on the film
gate.
• Remove the film gate.
Ensure that the adjustment shims are not bent,
dirtied or twisted during insertion.
Phillips
head
screws
rail
(std. 16)