INSTALLATION AND FRAMING INSTRUCTIONS:
The variety of installations possible for this air massage system may require framing procedures
other than those shown. Locate studs as required. Ensure roughing-in dimensions are proper,
plumb and square. Provisions must be made in all installations for an access opening for servicing
the air blower and controls. It is strongly recommended that an additional opening be provided for
access to the drain components. The apron should not be used as the primary access opening.
1. Position the air massage system into the installation opening and level the deck in both
directions, shimming the integral feet with attached baseboard as necessary. Refer to the Air
Bath Installation Table for nominal installation dimensions. Mark the final position of the
underside of the deck by tracing a line on to the studs (see Figure 1).
. Remove the air massage system and attach a 1 x 4 stringer to the studs, with the top of the
stringer touching the traced line.
The rim of the bath must not support weight.
TYPICAL PIER TYPE INSTALLATION
AS DESIRED
F
CUTOUT
AS DESIRED
E
CUTOUT
D
4
(610 mm)
1
(305 mm)
MOUNTING
SURFACE
WATERPROOF
SEALANT
BATH
TYPICAL RECESS INSTALLATION
4
(610 mm)
1
(305 mm)
D
A
B
C
LEVELING
STRINGERS
TILE
TILE
BEAD
STRIP
LEVELING STRINGER
1 x 4 (not for support)
BATH
ADHESIVE
SEALANT
WALLBOARD
NOTE: Tile bead kit not included
and must be purchased separately.
D
TYPICAL
INSTALLATION
FIGURE 1
3. Install supplied cable drain components to the air massage system according to the enclosed drain installation
instructions. Before replacing your air bath for final installation, be certain that an opening has been provided in
the sub-floor for the drain. See the roughing-in drawing for suggested opening size (shadowed) and location
dimensions. The drain/overflow of the bath extends below the bottom of the bath. Note that this requires a cutout
in the floor.
4. Replace air massage system and re-shim the integral support feet with attached baseboard, shimming the entire
length of the baseboard as needed. Secure the shims using construction adhesive, silicone or equivalent
materials.
The rim of the bath must not support weight. Any finish material such as tile or wall board must be
self-supporting if it contacts the deck of the bath.
!
!
ACCESS PANEL MUST BE LOCATED
ON THE SAME SIDE AS THE MOTOR.
ALLOW OPEN FRAMING ON PUMP/MOTOR
END FOR SERVICE.
ACCESS PANEL MUST BE LOCATED
ON THE SAME SIDE AS THE BLOWER.
ALLOW OPEN FRAMING ON
BLOWER END FOR SERVICE.
UNLESS AN ACCESS OPENING OF AT LEAST 12" X 24" (305 X 610mm)
IS PROVIDED, WARRANTY SERVICE WILL NOT BE PERFORMED.
UNLESS AN ACCESS OPENING OF AT LEAST 12" X 24" (305 X 610mm)
IS PROVIDED, WARRANTY SERVICE WILL NOT BE PERFORMED.
NOTE:
FRONT EDGE
OF BATH MUST
BE SUPPORTED
BY STUD WALL OR
AMERICAN STANDARD
APRON KIT
** USE CUTOUT TEMPLATE PROVIDED FOR 70 MODEL
NOTICE:
DO NOT BUILD THE SURROUNDING STRUCTURE BEFORE RECEIVING YOUR AIR BATH.
STRUCTURE MEASUREMENTS SHOULD BE VERIFIED AGAINST THE ACTUAL AIR BATH
RECEIVED TO ENSURE PROPER FIT.
AIR BATH INSTALLATION TABLE
DIM.
DESCRIPTION
A
B
C
D
E
F
5-3/4"
3-3/4"
41-3/4"
1"
5"
40-1/"
151mm
1511mm
1060mm
533mm
1473mm
101mm
Nominal tub length recess opening
Nominal tub apron support opening
Nominal tub width recess opening
Nominal tub height opening
Nominal tub length cutout
Nominal tub width cutout
71-3/4"
3-3/4"
41-3/4"
0"
70"
40-1/4"
13mm
1511mm
1060mm
50mm
177mm
10mm
1-1/"
67"
36-1/"
45mm
170mm
7mm
**
2748 2742
AIR BATH MODEL NUMBER
2709
3571 3572 3573 3574 3575