A SERVICE OF

logo

3
1)
OEL = Occupational Exposure Limit
Original Instructions
ATTIX 9 H/M
Dust Class M (medium). The dusts which belong to this class
are: dusts with OEL values
1)
> 0.1 mg/m³ as well as saw dust.
The machine is tested in its entirety by vacuums for this dust
class. The maximum degree of permeability is 0.1% and the dis-
posal must be low dust.
Dust Class H (high). The dusts which belong to this class are:
dusts with OEL values
1)
, all carcinogenic dusts and dusts
which are mixed with pathogenic agents. Vacuums for Dust
Class H are tested in their entirety and have a maximum degree of
permeability of 0.005%. The disposal must be dust free.
The air flow in Safety Vacuum systems has to be strictly controlled to
achieve a minimum flow rate of Vmin = 20 m/s in the suction hose.
The vacuum cleaners ATTIX 965-0H/M SD XC and ATTIX 965-2H/
M SD XC are suitable to pick up
• dry, nonflammable dust, non flammable liquids, sawdust and haz-
ardous dusts with OEL values
1)
, carcinogenic dusts, dusts contain-
ing germs
When dust removers are used, the rate at which air is exchanged
in the room must be adequate if the exhaust air from the vacuum
cleaner is blown into the room (please observe regulations valid in
your country).
The vacuum cleaner is suitable for commercial use, such as e.g. in
• Hotels, Schools, Hospitals, Factories, Shops, Offices, Hire shops
Any other use is considered as improper use. The manufacturer ac-
cepts no liability for any damage resulting from such use. The risk for
such use is borne solely by the user.
Proper use also includes proper operation, servicing and repairs as
specified by the manufacturer.
Transport
1. Before transporting the dirt tank, close all the locks.
2. Make sure that both plugs are inserted in fittings.
3. Do not tilt the cleaner if there is liquid in the dirt tank.
4. Do not use a crane hook to lift the cleaner.
Storage
1. Store the appliance in a dry place, protected from frost.