System Default Settings
Network
When using this unit on a network, go to SET UP
section = [System] = [Network], and set the
[Network] command to “ON”. Then go to SET UP
section = [System] = [Network], and set the
[DHCP/Manual] command either to use DHCP
(Dynamic Host Configuration Protocol) or input the IP
address used, together with sub-net mask and
Gateway address.
If “DHCP” is selected, confirm that a DHCP server in
fact exists. If no server exists, a longer time will be
required for the unit to boot to the idling condition
when the power is turned on. When “DHCP” is
selected, the [IP Address] command will display the
address automatically allocated to the recorder.
SET UP section = [System] = [Network]
SET UP section = [System] = [Network] = [DHCP/
Manual] = [DHCP]
SET UP section = [System] = [Network] = [DHCP/
Manual] = [Manual]
Note:
Be very careful when setting IP address, sub-net
mask, and Gateway addresses. Failure to set the
correct values may not only make it impossible to
connect to a network, but cause malfunctions
throughout the network. If you are unsure of the
proper values to set for these items, consult your
network administrator.
UPS Support
Whenever the power to this unit is turned OFF, the
unit performs a shutdown operation. An unintentional
power interruption can result in the power being
disconnected without the shutdown operation being
performed thus possibly causing malfunctions. In
order to avoid such malfunctions, we recommend
adding an uninterrupted power supply (UPS) to your
system.
By going to SET UP section = [System] = [UPS
Setting] = [Model], you can select APC Smart-
UPS 700 or Smart-UPS 500
(Note)
.
Note:
Smart-UPS 500 is for use in Japan only. Also, if the
power is interrupted when a UPS is connected, the
time before automatic shutdown is initiated can be
set to 30 seconds or 60 seconds (SET UP section
= [System] = [UPS Setting] = [Shutdown
Delay]). In this way, the shutdown operation will be
avoided if normal power is restored within the
selected time interval.
SET UP section = [System] = [UPS Setting]
Use the UPS products below, manufactured by
AMERICAN POWER CONVERSION CORP. (APC).
Smart-UPS 700VA
(Part Number: SU700NET)
Connection of other manufacturers’ UPS still works,
but does not communicate directly with the PRV-LX1.
When connecting this unit to the UPS, always use
the cables supplied with the UPS unit.
Before using the unit with a UPS, be sure to consult
the operating instructions accompanying the UPS
product.