22
SCAN LOCKOUT
If a programmable auxiliary key is programmed with
Scan Del/Add, each system can be locked out of the
scan sequence manually. The delete indicator ( s ) will
appear on the display when the selected system is
locked out.
SCAN REVERT
You can select revert systems and groups using the
encoder and the System or Group keys.
Six types of Scan Reverts which can be programmed by
your dealer are available:
• Last Called Revert: The last system/ group received is
assigned as the new revert system and group.
• Last Used Revert: The last system/ group responded to
is assigned as the new revert system and group.
• Selected: The last system/ group selected is assigned as
the new revert system and group.
• Selected + Talkback: If the system/ group has been
changed during Scan, the newly selected system/ group is
assigned as the new revert system and group. The
transceiver “talks back” on the current receive group.
• Priority: If your dealer has programmed a Priority
channel, this channel is the revert system and group.
• Priority + Talkback: If your dealer has programmed a
Priority channel, this channel is the revert system and
group. The transceiver “talks back” on the current receive
group.