IBM 760EL/ELD (9547) Clock Radio User Manual


 
Symptom / Error FRU / Action in Sequence
110
(Planar parity.)
1. Go to “Memory
Checkout” on
page 269.
2. DIMM Card
3. The computer is
attached to the
expansion unit.
4. System Board
111
(I/O parity.)
1. Go to “Memory
Checkout” on
page 269.
2. System Board
161
(Dead battery.)
1. Go to “Checking the
Backup Battery” on
page 275.
2. Backup Battery
3. System Board
163
(Time and Date was not
set.)
1. Reseat the keyboard
connector on the
system board.
2. Set Time and Date.
3. System Board
173
(Configuration data was
lost.)
1. Reseat the keyboard
connector on the
system board.
2. Select OK in the error
screen; then set the
time and date.
3. Backup Battery
4. System Board
174
(Configuration error:
Perform“Checking the
Installed Devices List” on
page 293 before changing
any FRUs.)
1. Check Device
Configuration.
2. System Board
3. Diskette Drive
Assembly
4. Hard Disk Drive
Assembly
184
(POP check sum error.)
1. Reset the POP
(power-on password)
in Easy-Setup.
190
(Depleted battery pack was
installed when the power
was on.)
1. Go to “Checking the
Battery Pack” on
page 274.
191XX
(PM initialization error.)
1. System Board
195
(The configuration read from
the hibernation area does
not match the actual
configuration.)
1. Check if the
configuration was
changed.
For example, check if
the DIMM card is
added.
280 IBM Mobile Systems - ThinkPad HMM Volume 3