REMOVING THE MAIN POWER PANEL
1. Power off the chair then unplug it.
2. Using a utility blade, peel the label off the main power panel, located on the left-hand side of the chair (Fig.1).
Note: Be sure to record the serial number that is printed on the power panel label before discarding it.
The serial number is required for warranty service.
3. Using a Phillips-head screwdriver, remove the two screws that secure the power panel to the chair (Fig.1).
4. Using a flat-head screwdriver, pry the panel out of the chair enough to expose the connectors, then disconnect
the connectors (Fig.2).
5. Remove the power panel from the chair (Fig.3).
Tools Required: Phillips-head screwdriver, utility blade, flat-head screwdriver.
SAVE ALL REMOVED PARTS FOR USE DURING REASSEMBLY
1
To ensure that Human Touch
®
products are repaired in a manner that is fully consistent with the practices used during the manufacturing process, Human Touch requires that all
product repairs are performed using only factory-new parts and in accordance with these product repair instructions.
SERVICE LEVEL: 2
(Fig.2)
X1103
REPLACING THE MAIN POWER PANEL
Jan 04, 2010
iJoy-2400
Peel the label off
(Fig.1)
Power panel
Power panel
flat-head screwdriver
Connectors
(Fig.3)
Power panel removed
Power panel