Black Box Black Box High-Density Media Converter System II Portable Media Storage User Manual


 
5
LNK/ACT
FDX/COL
TEMP
PS
FAN A / FAN B
Glows green when a link is established on port.
Blinks green when data activity occurs.
Glows yellow when port is in Full-Duplex mode.
Blinks yellow when port is operating in Half-
Duplex mode and collisions occur.
Glows yellow when temperature of unit surpasses a
user-defined level.
Glows yellow when one module malfunctions.
Glows yellow when a fan malfunctions.
Installing the 20-Slot Rackmount Chassis
Install the chassis first before installing any modules into a 20-Slot Rackmount Chassis. When
installing the chassis, be sure to observe the following precautions to prevent electrical or
mechanical damage:
1.
Protect the chassis from exposure to sunlight and electrical or magnetic fields.
2.
Ensure that the equipment rack remains stable, even with the addition of the chassis and
its associated cabling.
To install 20-Slot Rackmount chassis:
1.
Have four #10 screws and four clip nuts available (hardware may vary depending on
rack type). The rest of the hardware is supplied with the unit.
2.
Locate a suitable location in the rack for installation and secure the clip-nuts onto the
mounting rails. Use screws to attach the chassis to the rack.
3.
Plug the chassis into a reliable, filtered power source.
4.
Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the
operating ambient temperature of the rack environment may be greater than room
ambient. Therefore, consideration should be given to installing the equipment in an
environment compatible with the maximum ambient temperature (Tma) specified by the
Black Box.
5.
Reduced Air Flow - Installation of the equipment in a rack should be such that the
amount of air flow required for safe operation of the equipment is not compromised.
6.
Mechanical Loading - Mounting of the equipment in the rack should be such that a
hazardous condition is not achieved due to uneven mechanical loading.