Axis Communications Q2901-E Clock Radio User Manual


 
AXIS Q2901-E Temperature Alarm Camera
Technical Specifications
Technical Specifications
Function/group
Item
Specications
Model
AXIS Q2901–E
Image sensor Uncooled Micro bolometer 336x256 pixels, pixel size 17 µm
Spectral range: 8-14 µm
Lens
9 mm: f 1.25 FoV horizontal 35°, vertical 27°; min. focus distance: 2.1 m (78.7 in)
19 mm: f 1.25 FoV horizontal 17°, vertical 13°; min. focus distance: 9.5 m (354.3 in)
Temperature
detection range
The size of a monitored object is recommended to cover at least 10x10 pixels in 336x256.
Camera
Sensitivity
NETD < 50 mK
Object
temperature
range
-40 to 550 °C (-40 to 1022 °F)
Thermography
Temperature
accuracy
Below 100 °C (212 °F): +/- 5 °C (+/- 9 °F) accuracy
Below 150 °C (302 °F): +/- 5% accuracy
Over 150 °C (302 °F): +/- 20% accuracy
Video
compression
H.264 (MPEG-4 Part 10/AVC), H.264 Main and Baseline Prole Motion JPEG
Resolutions
Sensor is 336x256. Image can be scaled up to 720x576
Frame rate Up to 8.3 fps
Video streaming
3 individual streams* in H.264 and Motion JPEG: simultaneous,individually congured
streams in max. resolution at 8.3 fps Controllable frame rate and bandwidth. VBR/CBR
H.264 * 3 individual streams with same palette
Image settings
Automatic gain control, Exposure zones, Gain, Rotation, Palette, Isothermal palette,
Compression, Mirroring, Text and image overlay, Sharpness, Axis Corridor Format
Palette White-hot
Black-hot
Planck
Axis
Rainbow
Red-hot
Nightvision
Video
Isotherm palette Iso-Fire-WH
Iso-Fire-BH
Iso-Planck-WH
Iso-Axis-WH
Iso-Midrange-WH
Iso-Midrange-BH
Iso-Rainbow-WH
Audio streaming Two-way, Full duplex
Audio
compression
AAC LC 8/16 kHz
G.711 PCM 8 kHz
G.726 ADPCM 8 kHz
Congurable bit rate
Audio
Audio
input/output
External microphone or line input, line output
63