Axis Communications Q2901-E Clock Radio User Manual


 
AXIS Q2901-E Temperature Alarm Camera
Detectors
6. For detection type Increase: Enter the increase rate (F) in degrees per seconds in the Increase rate elds.
- The Y-axis: the degrees in Celsius or Fahrenheit
- The X-axis: the increase time in seconds
-
+
F
7. Click Save to save your settings or continue to the Advanced Settings section to set additional detection conditions.
Advanced Settings
1. In a temperature detection zone: Select Advanced Settings to show additional detection settings.
2. Enter an emissivity value (0.50 – 1.00). in the Emissivity eld. Different materials have different emissivity levels. See
Material Emissivity Table on page 32.
3. Select Maximum temperature in the zone or Minimum temperature in the zone as the base for temperature detection:
- Maximum temperature in zone (C): The temperature detection (Above / Below / Increase) will be based on
the maximum temperature in the zone.
- Minimum temperature in zone (C): The temperature detection (Above / Below / Increase) will be based on
the minimum temperature in the zone.